Tel.: +86 13358378970
E-mail: sales6@saulplc.com
Colour:new
Warranty: 12 months
Lead Time:3-day working day
Price: Please contact us
Shipping Port: Xiamen, China
Payment:T/T
Express cooperation: fedex, DHL, UPS and your express account
Service: Professional Sales provides 24 hours /7 days online service
PRODUCT DETAIL
VME421H-D-2 BENDER Voltage Monitor
Product information:
Brand:DANAHER Model number:VME421H-D-2
Lead Time:3-day working da Country of origin: Germany
Price: Please contact us Product weight:0.56kg
HS: 8517623990
Product technial information:
The voltage monitor VME421H monitors AC/DC systems in the frequency range of
DC/15…460 Hz for undervoltage, overvoltage, underfrequency or overfrequency.
Device variant -1 is suitable for the nominal voltage range Un = 9.6…150 V, device
variant -2 for Un = 70…300 V. The supply voltage is taken from the nominal voltage
being monitored Un.
In order to meet the requirements of the applicable standards, customised parameter
settings must be made on the equipment in order to adapt it to local equipment and
operating conditions. Please heed the limits of the range of application indicated in the
technical data.
• Voltage and frequency monitoring of single-phase machines and electrical installations
• Earth fault monitoring in medium-voltage systems via voltage transformers
• Monitoring of battery systems
• Switching machinery and equipment on and off at a certain voltage level
After connecting the device for the first time, the nominal system voltage will be determined
(PrE run), and the response values for overvoltage and undervoltage as well as for
underfrequency and overfrequency will automatically be set. When no voltage is determined
within a nominal system voltage range (PrE run), the response values will be set to
the minimum or maximum voltage. In this case, the message “AL not SET” appears on the
display. As long as no button is pressed, a nominal system voltage is being searched cyclically
(PrE run). If a button is pressed, the search will be interrupted and the message “AL not SET”
disappears. In this case, the appropriate response values have to be set in the menu.
When activating the frequency monitoring function, the preset frequency will automatically
be stored.
Contact information:
Contact person:Luna Chen
Email Address::sales6@saulplc.com
WhatApp: +86 13358378970
We look forward to your inquiry and will get back to you as soon as possible.
Related models:
BENSHAW | RSi-015-SG-4B |
BENSHAW | RSI-015-S-2DB |
BENSHAW | BIPC-300034-01 |
BENSHAW | BIPC-300047-01 |
BENSHAW | KPMX3LLCD |
BERGER | TLC411PSF |
Berger | WDPM3-314 |
BERGER LAHR | VRDM 566/50 LNA |
BERGER-LAHR | WD5-008.051-00 |
BERGHOF | RDC2 |
BERGHOF | CDIO 16/16-0.5 |
BERGHOF | RDC2 |
BERGHOF | CEDIO-S |
BERGHOF | RTEMP8/16 |
BERGHOF | QAIO16/4-V |
BERKELEY | S64-3450 |
BERTHOLD | 81072-2/LB352-2 |
BERTHOLD | 81072-8/LB352-2 |
Bihl+Wiedemann | BWU1488 |
BIOPTICS INC | 2010-00005 |
Navigation
Add.: 9D, 9th Floor, Huguang Building, Hubin West Road, Siming District, Xiamen City, Fujian Province, China
Tel.: +86 13358378970
Mob.: +86 13358378970
E-mail: sales6@saulplc.com
WhatsApp: +86 13358378970
Wechat: +86 13358378970