Tel.: +86 13358378970
E-mail: sales6@saulplc.com
FOXBORO P0916JT Power module
Quantity available:10
The colour:NEW
Warranty: 12 months.
Lead time: 1-2 working days.
Terms of payment: Paypal、T/T 、 Western Union.
Courier partners: DHL, UPS, TNT, FedEx and EMS.
PRODUCT DETAIL
Welcome, thank you for your trust, The seller has more than $1526000 worth of industrial control products inventory.hope we can help you solve your problem!!!
We Can transport to the world!!!
*******************************************************
FOXBORO P0916JT Power module In Stock
As the measurement goes below the lower control point, the control valve fully opens (or closes).
This reverses the measurement but there is no change in control action until the measurement
crosses the upper control point, at which time the valve fully closes (or opens). One control point
is determined by the setting index and the other control point by the gap width (see example
below).
Gap width = difference between control points divided by span.
For example, if measurement scale is graduated from 20 to 120, and control points are to
be 70 and 90, gap width
To reverse control action, push up latch and rotate dial so that latch is on other side of
stop, then push down latch (see figure below).
3. Turn PROPORTIONAL BAND adjustment (on control dial) to 400 or to safe high
value.
Turn DERIVATIVE adjustment (if present) to 0.05.
Turn RESET adjustment (if present) to 50 or safe high value.
4. Open shutoff valves and close bypass valve.
5. Turn set point knob (or adjust remote set point, if present) so that set point index is at
desired value.
6. If controller is not equipped with optional automatic-manual transfer, proceed to
Step 7. If controller is equipped with transfer, start up in manual as follows:
a. Move transfer switch to manual
b. Turn on 20 psi (140 kPa) air supply. Blow out filter.
c. Adjust output with regulator so that measurement pointer is held as close as
possible to set point index.
d. After measurement has stabilized, move transfer switch to automatic. Process is now on automatic control.
7. If controller is not equipped with optional automatic-manual switch, turn on 20 psi
(140 kPa) air supply. Blow out filter.
8. After measurement has stabilized, adjust proportional band, derivative, and reset
controls (if present) for best process operation.
Product details:
FOXBORO P0916JT Power module
Contact information:
Contact person:Luna Chen
Email Address::sales6@saulplc.com
WhatApp: +86 13358378970
We look forward to your inquiry and will get back to you as soon as possible.
We have the same series of models in stock. If you don't find the model you need, please contact us and we will provide you with an official quotation!
FOXBORO | P0914SQFBM201 |
FOXBORO | P0914SVFBM203 |
FOXBORO | P0916CPFCM10EF |
FOXBORO | P0922YHFBM201b |
FOXBORO | P0922YJFBM201c |
FOXBORO | P0922YKFBM201d |
FOXBORO | P0926EQFBM202 |
FOXBORO | P0922UAFBM203b |
FOXBORO | P0922UDFBM203c |
FOXBORO | P0914SYFBM204 |
FOXBORO | P0914XGFBM205 |
FOXBORO | P0916CQFBM206 |
FOXBORO | P0914TDFBM207 |
FOXBORO | P0914WHFBM207b |
FOXBORO | P0917GYFBM207c |
FOXBORO | P0914TBFBM208 |
FOXBORO | P0914XLFBM212 |
FOXBORO | P0914XNFBM213 |
FOXBORO | P0914XQFBM214 |
FOXBORO | P0922VUFBM215 |
FOXBORO | P0922VVFBM216 |
FOXBORO | P0914TRFBM217 |
FOXBORO | P0916RHFBM219 |
FOXBORO | P0922VWFBM218 |
FOXBORO | P0917HAFBM220 |
Navigation
Add.: 9D, 9th Floor, Huguang Building, Hubin West Road, Siming District, Xiamen City, Fujian Province, China
Tel.: +86 13358378970
Mob.: +86 13358378970
E-mail: sales6@saulplc.com
WhatsApp: +86 13358378970
Wechat: +86 13358378970