Hong Kong Saul Electric Co., Ltd.

Tel.: +86 13358378970

E-mail: sales6@saulplc.com

  • Emerson  DeltaV SE4001S2T2B5

  • Emerson  DeltaV SE4001S2T2B5

  • Emerson  DeltaV SE4001S2T2B5

Emerson DeltaV SE4001S2T2B5

Emerson  DeltaV SE4001S2T2B5 IO module

Quantity available:10

The colour:NEW

Warranty: 12 months.

Lead time: 1-2 working days.

Terms of payment: Paypal、T/T 、 Western Union.

Courier partners: DHL, UPS, TNT, FedEx and EMS.



PRODUCT DETAIL

Welcome, thank you for your trust, The seller has more than $1526000 worth of industrial control products inventory.hope we can help you solve your problem!!!

  We Can transport to the world!!!

*******************************************************
Emerson  DeltaV SE4001S2T2B5 IO module In Stock

The DeltaV SIS logic solvers execute extensive self-testing on a continuous basis to detect potential faults. Faults detected by logic solver diagnostics can be associated with the logic solver itself or associated with ffeld devices, ffeld wiring, or other conditions not related to hardware.DeltaV SIS provides standard alarms to annunciate faults detected by logic solvers in the operator interface. No special conffguration is required. When a diagnostic alarm occurs, it appears on the alarm banner of the operator interface. The operator is shown the type of alarm (failed, maintenance, etc.), as well as text for the active condition or “multiple conditions” if more than one alert condition is active for the particular alarm.With DeltaV SIS, events are automatically generated as function blocks are executed within a module scan. Events are time stamped with a resolution of <1 ms, and they are recorded in the sequence that they occur in the Event Chronicle. When using standard function blocks such as input blocks, voter blocks, and cause and effect blocks, a standard set of events are automatically generated without special conffguration or programing required. For example, I/O failures, trip limits, ffrst outs, and other similar events are automatically time stamped by function blocks and recorded in the Event Chronicle. When a process variable exceeds the trip limit, DeltaV SIS records the event along with the analog value and the trip condition.

2.designed for 3 wire analog transmitters and can be used with the AI 4-20mA HART CHARM. The ffeld power is supplied from the injected power bus on the baseplate, but the power is not removed from the ffeld device when the AI CHARM is removed from the baseplate. There is a Green LED on the terminal block that indicated power is supplied to the ffeld and the 2A fuse also functions as a means to disconnect power from the ffeld device. Although this terminal block was introduced in 2017, it is backwards compatible to any version of DeltaV with Electronic Marshalling.Although any signal type can be installed in any location on the CHARM baseplates, it is recommended that AC voltage circuits be separated from low voltage signals to comply with safety recommendations and to mitigate induced noise in the signals. Standard Terminal blocks, Fused Injected Power terminal blocks and Relay Output Blocks can be used on the same carrier, typically, to allow the use of DO 24V DC isolated CHARMs on higher wattage and 3-wire devices alongside of standard 24V DC instrumentation signals or relay contacts.The Terminal Blocks contain keying posts that are automatically set and locked to the unique position of the installed CHARM. The keys prevent the insertion of an incorrect CHARM during maintenance activities.

Product details:

Emerson  DeltaV SE4001S2T2B5 IO module

image.png


Contact information:

Contact person:Luna Chen

Email Address::sales6@saulplc.com

WhatApp: +86 13358378970

We look forward to your inquiry and will get back to you as soon as possible.

05886c11f9b2508691faab4fab6e403.png                   df2a1cf2e56d2295f8a6ef2e2406563.png



We have the same series of models in stock. If you don't find the model you need, please contact us and we will provide you with an official quotation!

EMERSON12P0555X132
Emerson12P0631X012
EMERSON12P0678X022
EMERSON12P0678X032
EMERSON12P0681X072
EMERSON12P0683X082
EMERSON12P1064X072
EMERSON12P1064X08R
EMERSON12P1064X122
EMERSON12P1442X042
EMERSON12P1509X052
EMERSON12P1731X082
EMERSON12P1732X042
EMERSON12P1732X062
EMERSON12P2186X012
EMERSON12P2471X042
EMERSON12P2506X062
Emerson12P2531X122
EMERSON12P2536X042
Emerson12P2843X022







Contact Us

Add.: 9D, 9th Floor, Huguang Building, Hubin West Road, Siming District, Xiamen City, Fujian Province, China

Tel.: +86 13358378970

Mob.: +86 13358378970

E-mail: sales6@saulplc.com

WhatsApp: +86 13358378970

Wechat: +86 13358378970

Saul Electric is not an authorised distributor or representative of the manufacturers featured on this website. Designated brand names and trademarks featured on this website are the property of their respective owners.